Instructions for use of the Helix (Straumann) implant | World-Implant

Helix (Straumann) Bauer’s Implants

A single 22° orthopedic conical platform forms a tight seal at the implant abutment connection interface.

Deep thread produced over the total length of the implant contributes to a good primary stability during implant installation and reduces pressure on the cortical bone.

The unique shape of the antirotation furrow reduces axial load and reduces excess pressure on the bone during installation

The flattened apical part prevents damage to the Schneiderian membrane.

The product line of the Company originally included the implant sizes that could cover most clinical events. Designers and clinicians have conducted a detailed analysis of required shapes, diameters and lengths, in consequence of which we can maintain that with Bauer’s Implants implants it is easy to achieve the most predictable positive results during rehabilitation of patients.

All implants in a linear series have exactly the same taper shape (in the context of one given diameter) along the length from the neck to a distance of 6 mm.

Helix (Straumann) Ø 3.5 implants

Helix implants with a diameter of 3.5 mm

Vendor code IH 35070 IH 35085 IH 3510 IH 35115 IH 3513
L (мм) 7.0 8.5 10.0 11.5 13.0
Ø (мм) 3.5

It provides the same strength in the entire linear series and stability of clinical and physical parameters, regardless of the length of implant used. When performing the fatigue test, the weak section of all implants is measured at a distance of 3 mm from the implant neck. Therefore, it’s fair to say that the cross section of all implants to diameter in a linear series is equally reliable and equal in strength.

Besides, according to clinical studies, the first 6 mm of implant length have a dominant role in osseointegration.

Helix (Straumann) Ø 4.0 implants

4.0mm Helix Implants

Vendor code IH 40070 IH 40085 IH 4010 IH 40115 IH 4013
L (мм) 7.0 8.5 10.0 11.5 13.0
Ø (мм) 4.0

Helix (Straumann) Ø 4.5 implants

Helix implants with a diameter of 4.5 mm

Vendor code IH 45070 IH 45085 IH 4510 IH 45115 IH 4513
L (мм) 7.0 8.5 10.0 11.5 13.0
Ø (мм) 4.5

blind screw bauers CS 2040

All implants are completed with a closure screw

Vendor code CS 2040
L (мм) 8.0
Ø (мм) 3.5

Length (L) should be understood to mean the length of implant. Drills are marked 0.5 mm longer than the implant length, which corresponds to the principle of implant installation 0.5 mm below the cortical layer. Diameter (Ø) should be understood to mean the average diameter over the total length of implant.

Usage protocol

protocol for the use of helix implants